Selective redaction profiles: choosing between Zero-Capture, Zero-RF, and Full Six
Removing all six components is the default for SCIFs, but many healthcare, manufacturing, and courtroom programs need Wi-Fi or speakers to stay active. Use these four standard profiles to scope your order.
CBR Labs offers both 'Full Six' total redaction and selective per-component profiles. Buyers standardize on four baseline profiles: Profile A (Full Six for SCIFs/SAPFs), Profile B (Zero-Capture + Zero-RF with speakers retained for courtrooms), Profile C (Zero-Capture with Wi-Fi retained for hospitals and CMMC/ITAR plants), and Profile D (No-Camera Optical-Only for commercial cleanrooms).
- Every CBR Labs order can specify any subset of the six hardware groups: Cameras, Microphones, Speakers, Wi-Fi, Bluetooth, and Antennas (Cellular/GPS/NFC).
- Profile A (Full Six) is the gold standard for ICD 705 SCIFs and DoDM 5205.07 SAPFs.
- Profile C (Cameras, Mics, BT, Cell removed; Wi-Fi kept) is the workhorse for HIPAA bedside tablets and CUI/ITAR shop floors.
- Each unit's Certificate of Redaction explicitly documents which components were excised and which were retained.
When organizations first contact CBR Labs, they often assume hardware redaction is an all-or-nothing proposition. While our 'Full Six' redaction (cameras, microphones, speakers, Wi-Fi, Bluetooth, and cellular/GPS antennas) is the flagship specification for classified spaces, nearly half of our deployments use a selective profile tailored to a specific workflow.
Below are the four standard redaction profiles we build most frequently, along with the environments where each belongs.
Profile A: Full Six (Zero-Capture + Zero-RF + Silent)
Removes: Cameras, Microphones, Speakers, Wi-Fi, Bluetooth, and Cellular/GPS/NFC Antennas.
Used in: SCIFs, SAPFs, grand jury chambers, and strictly air-gapped defense enclaves where the device must be completely passive optically, acoustically, and electromagnetically.
Profile B: Zero-Capture + Zero-RF (Audio Output Retained)
Removes: Cameras, Microphones, Wi-Fi, Bluetooth, and Cellular/GPS/NFC Antennas. Retains: Speakers (or headphone audio out).
Used in: Jury deliberation rooms (for playing admitted audio/video exhibits), in-custody legal discovery review, and offline training tablets.
Profile C: Zero-Capture + Managed Wi-Fi Only
Removes: Cameras, Microphones, Bluetooth, and Cellular/GPS Antennas. Retains: 802.11 Wi-Fi (and optional speakers).
Used in: Hospital bedside and behavioral health units (HIPAA / 42 CFR Part 2), ITAR/CMMC manufacturing shop floors, and pharma cleanrooms where the tablet must sync with an EHR or ERP over enterprise Wi-Fi but must never record photos or audio.
Profile D: Optical-Only (No-Camera Tablet)
Removes: Front, rear, and IR cameras. Retains: Microphones, speakers, and wireless connectivity.
Used in: Commercial cleanrooms, trade-secret R&D floors, and facilities where voice/network collaboration is permitted but photography is strictly banned.
How to map your facility's threat model to the right component matrix
Over-redacting a tablet can handicap your operational workflow just as easily as under-redacting it can fail a security audit. For example, if a hospital privacy officer orders Profile A (Full Six—removing Wi-Fi along with cameras and mics) for bedside rounding iPads, nurses will discover the tablets cannot connect to Epic over the hospital WLAN without a wired Ethernet dongle.
Conversely, if a defense contractor orders Profile D (No-Camera only) for a SCIF, the SSO will reject the unit because the microphones and wireless radios are still present. Use this engineering decision tree to lock in the right specification before issuing your PO:
- Decision 1 — Is wireless networking permitted in the room? If NO (SCIF, SAPF, jury room, nuclear ESP), remove all RF (Profiles A or B). If YES on an accredited enterprise WLAN (hospital, CMMC shop floor, pharma cleanroom), retain 802.11 Wi-Fi and remove Bluetooth/Cellular (Profile C).
- Decision 2 — Must the tablet play audible sound? If the workflow plays admitted 911 audio in a jury room or patient education videos, retain speakers (or headphone jack) while removing all microphones (Profile B/C). If the room requires total acoustic transducer removal (SAPF/SCIF), remove speakers as well (Profile A).
- Decision 3 — Is rear-camera photography required inside an RF-quiet room? For Faraday forensic labs or EBR gauge verification, retain only the rear camera while removing the front camera, all microphones, and prohibited radios.
Ordering mixed profiles across a single enterprise contract
Large organizations frequently deploy different profiles across different zones of the same campus. CBR Labs tracks profile variants at the individual serial-number level:
- Define line items by profile on your PO: For example, Line 1: 40x iPad Air (Profile C — Shop Floor Wi-Fi); Line 2: 10x iPad Air (Profile A — SCIF Full Six).
- Color-coded or prefix-coded asset labeling: Each unit's CBR Labs QR tag and Certificate of Redaction clearly states its exact component matrix so a Profile-C shop tablet is never mistakenly carried into a Profile-A SCIF.
- Verify online via /v: Scanning any tablet's QR code displays the exact array of excised components (`['CAMERA','MIC','SPEAKER','WIFI','BT','ANTENNA']`).
Standard CBR Labs Hardware Redaction Profiles (A–D)
| Profile Code | Cameras | Microphones | Speakers | Wi-Fi | Bluetooth & Cell/GPS | Primary Deployment |
|---|---|---|---|---|---|---|
| Profile A (Full Six) | Removed | Removed | Removed | Removed | Removed | SCIFs, SAPFs, Grand Jury, Air-Gapped Enclaves |
| Profile B (Zero-RF + Audio Out) | Removed | Removed | Retained | Removed | Removed | Jury Deliberation, In-Custody Discovery, Offline Training |
| Profile C (Managed Wi-Fi Only) | Removed | Removed | Optional | Retained | Removed | Hospitals (HIPAA/Part 2), CMMC/ITAR Shop Floors, Pharma EBR |
| Profile D (No-Camera Optical) | Removed | Retained | Retained | Retained | Optional | Semiconductor Cleanrooms, R&D Labs, Commercial IP Zones |
Frequently asked questions
Does selective redaction cost less than Full Six redaction?
+
Because opening the tablet chassis, thermally cycling the display adhesive, performing QA verification, and generating the Certificate of Redaction are required on every job, pricing scales primarily with unit volume and model complexity—contact us with your profile and quantity for an exact quote.
Can a tablet redacted to Profile C (Wi-Fi retained) later be upgraded to Profile A (Full Six)?
+
Yes. A device that previously had only cameras and microphones removed can be returned to CBR Labs to have its remaining wireless radios excised and a new Certificate of Redaction issued.
Can we reference Profiles A, B, C, or D directly in our government Statement of Work?
+
Yes. Referencing the exact component matrix in your SOW ensures unambiguous bidding and faster contracting review.
Can we create a custom profile that isn't one of the standard four (A, B, C, or D)?
+
Yes. Profiles A–D are simply shorthand for the four most common matrices. Because every redaction is performed by trained technicians at the board level, you can specify any combination of components per line item.
How do we prevent employees from mixing up Profile A (Zero-RF) and Profile C (Wi-Fi retained) tablets?
+
In addition to the QR verification record at `/v`, we can print distinct second lines on the Avery 22805 QR asset tags (e.g., 'ZERO-RF · SCIF' vs. 'NO-CAM/MIC · WLAN') during intake labeling.
Written and reviewed by Rob Pfleghardt and the bench engineering team at CBR Labs LLC (5927 Tilbury Road, Alexandria, VA 22310). CBR Labs is an active SAM.gov-registered Woman Owned Small Business (CAGE 14Y35 · UEI K4MZG4KC1MY9) performing permanent, board-level hardware redaction on iPad and Android tablets.
Bench-level comparisons of Apple iPad, Samsung Galaxy Tab, and Google Pixel Tablet hardware architectures, SKU selection, post-redaction iPadOS/Android behavior, and lifecycle updates.
Why Apple doesn't sell a 'Non-Camera iPad' (and how enterprise and government buyers get one)
MDM vs. hardware redaction: why a policy is not a sensor
iPad vs. Samsung Galaxy Tab vs. Google Pixel Tablet: which redacts best?
Choosing the right iPad SKU for hardware redaction (and how to save $150/unit)
Know which profile your program needs?
Send us your profile letter (or custom component list), tablet model, and quantity for a same-day or next-day quote.